Model name:
Flat Roof - Insulation Above Timber Deck (Acoustic Membrane)
ROCKWOOL product used:
HARDROCK® Multi-Fix (DD)
Open1
2
3
4
5
6
7
8
Construction build-up:
- Gypsum plastering (1300)
- Standard Wallboard Plasterboard
- Unventilated air layer
- Plywood [500 kg/m3]
- Polyethylene/polythene, low density 0.15 mm
- HARDROCK® Multi-Fix (DD)
- Bitumen felt/sheet
- Bitumen felt/sheet
Variants:
-
Hardrock 0.135 m (U = 0.25 W/m²K)
Open -
Hardrock 0.140 m (U = 0.24 W/m²K)
Open -
Hardrock 0.145 m (U = 0.23 W/m²K)
Open -
Hardrock 0.155 m (U = 0.22 W/m²K)
Open -
Hardrock 0.165 m (U = 0.21 W/m²K)
Open -
Hardrock 0.170 m (U = 0.20 W/m²K)
Open -
Hardrock 0.185 m (U = 0.19 W/m²K)
Open -
Hardrock 0.190 m (U = 0.18 W/m²K)
Open -
Hardrock 0.105 m + 0.105 m (U = 0.17 W/m²K)
Open -
Hardrock 0.115 m + 0.105 m (U = 0.16 W/m²K)
Open -
Hardrock 0.085 m + 0.150 m (U = 0.15 W/m²K)
Open -
Hardrock 0.105 m + 0.150 m (U = 0.14 W/m²K)
Open -
Hardrock 0.085 m + 0.185 m (U = 0.13 W/m²K)
Open -
Hardrock 0.150 m + 0.150 m (U = 0.12 W/m²K)
Open -
Hardrock 0.185 m + 0.150 m (U = 0.11 W/m²K)
Open -
Hardrock 0.185 m + 0.185 m (U = 0.10 W/m²K)
Open